UV Modules
LIT 88MLV UV Disinfection Systems have modular design for flexible, easy
system integration, installation and operation. The key component of the 88MLV
series UV system is 88MLV-36A module consisting of 36 vertically placed lamps.
Lamps are arranged in four parallel rows of 9 lamps in each row. The modules can
be installed in the channel separately or can be grouped in series and/or in
parallel. Each module has quick-attachment cover lid that allows the lamps to be
checked or replaced without having to remove the module out of the water flow or
disturb the quartz sleeve seals.
Ballast cabinets
Electronic ballast cabinets are installed near each UV bank above the
channel. Each UV module is connected to the electronic ballast cabinet through a
pair of waterproof plugs. High efficiency electronic ballasts are installed
inside the cabinets. Each cabinet has a small LCD display to provide the
information about UV module and UV lamp status in each respective UV bank.
Power supply cabinets
For large-scale UV systems incorporating multiple UV channels the power
supply of the UV system is realized through separate Distribution Power Supply
Cabinet. In the cabinet there are overcurrent protection fuses, main power
switch and power switches for each UV bank. The electricity requirements for UV
system are 380 V / 3 phase / 50 Hz. From the distribution power supply cabinet
there are electrical connections to the electronic ballast cabinets, water level
control system, motor drives of the shut-off sliding gates and cleaning
system.
Operating and Control system
Control and operation of the UV plant is provided through a Control Cabinet.
On a front door of the cabinet there is a control panel with graphical user
interface to control the UV system. The UV system can be operated both in
automatic and manual modes. The control system is implemented on the base of
industrial PLC system. There is an optional possibility to transmit all
operational data from the UV system to the main WWTP control centre through the
standard industrial serial bus. The Control System incorporates the data logging
function for recording all operating parameters as well as alarm history. The
minimum capacity of the log register is 1 year.
|